ACI Power Meter Current Transformers (Standard Grade)

Features

  • Designed to convert an AC operating current into a low-voltage AC signal.
  • Use with microprocessor-based circuits that require maximum accuracy and precision.
  • All of the Split Core CTs come standard unterminated with ferrules for easy connection to any of the Single or 3 Phase Dent power meters.
  • Any of the split-core CTs can be used with any of the Powerscout™ PS3037, PS24, PS12HD, and PS48HD Power Meters.
  • The CT-SCM and CT-SCL Series Current transformers are a cost-effective alternative to the Rocoil™ CTs.
  • Selection should be based on the maximum and minimum currents being monitored.
  • Flexible Rocoil™ CTs provide a higher level of accuracy and should be used in applications with current levels of 600 Amps and larger.
  • The CT-HSC and CT-HMC Series current transformers come with snap-acting hinged designed to provide great performance.
Enquiry

Automation Components, Inc. (ACI) creates, manufactures, and distributes building automation sensors for the heating, ventilation, and air conditioning (HVAC) Industry. Dpstar is ACI Authorised Distributor in Malaysia. Our product lines include Temperature Sensors, Relative Humidity Sensors, Current Sensors, Pressure Sensors, Gas Sensors, and Wireless Sensors.

The Split Core Current Transformers are designed to convert an AC operating current into a low-voltage AC signal for use with microprocessor-based circuits that require maximum accuracy and precision. All of the Split Core CTs come standard unterminated with ferrules for easy connection to any of the Single or 3 Phase Dent power meters. Any of the split core CTs can be used with any of the Powerscout™ PS3037, PS24, PS12HD, PS48HD Power Meters in applications where typical power measurements are required and reduced accuracies are acceptable. Where higher accuracies are required, refer to the Revenue Grade CTs product data sheet for more detailed product information. For best accuracy, the CTs should be selected based upon the size of the conductors to be monitored by selecting the proper window size and using the expected maximum and minimum currents expected for the piece of equipment or branch circuit.

The acceptable Measurement Current Range is referenced in ordering grid table on the back of the product data sheet. The CT-SCM and CT-SCL Series Current transformers are a cost effective alternative to the Rocoil™ CTs but overall selection should be based upon the maximum and minimum currents being monitored. All currents below the minimum measurement range will cause a “Snap to Zero” to occur which means that the power meter will show that no current is being consumed at that time thus affecting the reliability of your data. Flexible Rocoil™ CTs provide a higher level of accuracy and should be used in applications with current levels of 600 Amps and larger. The CT-HSC and CT-HMC Series current transformers come with a snap-acting hinged design are designed to provide great performance, lower operating currents and easy installation in both new and retrofit installations. Extending the leads on all of the Split Core CTs can be done in the field when using the same style and type of wire that is provided with the CTs as discussed in the Current Transformer Lead Extension Whitepaper or ordered from the factory for an additional cost and lead time.

The Split Core mV Output Current Transformers are covered by ACI’s One (1) Year Limited Warranty.

Dimension

Applications

  • Energy and Demand Metering
  • Load Surveys
  • LEED/Green Projects
  • ROI / Project Justification

Specification

Download

ACI Power Meter CurrentTransformers (Standard Grade)_DpstarGroup