Advanced Documenting Multifunction Calibrator Hermometer – AOIP CALYS 150

Features

  • Scaling allows process signals to be displayed in % of FS or in all other units. This function also allows sensors to be corrected after a calibration.
  • With 100 values manually set, CALYS 150 enables users to draw a generation curve.
  • CALYS 150 is able to be used as a transmitter. Measurement input is copied on the output with scaling.
  • In temperature or pressure mode, CALYS 150 can control electronic thermostat and press stat trigger levels.
Enquiry
Category:

CALYS 150 field documenting multi function calibrator is the top instrument of the range. It is the perfect tool for advanced process maintenance and use on test bench in all industries. Suitable for all field and lab measurements, it can simultaneously measure and generate over two isolated channels various signals of temperature, resistance, process, pressure and frequency in one single instrument.

CALYS 150 does not only work as a simulator (IN / OUT) but also as a dual channel thermometer (IN / IN) to perform comparison calibration. It calibrates HART transmitters (HART communicator integrated into ACL500 modem) and thermistors. Providing extended functionalities (temperature simulation, scaling, steps, synthesizer, statistical functions…) and audit trails, CALYS 150 complies with both 21 CFR Part 11 and NADCAP Heat Treatment standards and makes advanced data exploitation and full data traceability easier.

High performances for CALYS 150, for advanced use:

  • Temperature Up to 0.005 % RDG
  • Resistance Up to 0.006 % RDG and 50 KΩ range
  • Current: Up to 0.007 % RDG and 100 mA range + Loop Supply 24 V
  • Voltage: Up to 0.005 % RDG and 50 V range
  • Frequency: Up to 0.01 % RDG and 100 KHz range
  • Pressure: With an external pressure module (comparison calibration with a pressure pump)

Using this user-friendly instrument, calibration tasks can be quickly carried out over the whole process chain. Take the 900 g documenting process calibrator to the field with you during the whole week with 10 calibration procedures stored in the device. Run the procedure after connecting the probes to the instrument (Easy connect system®) and save the results for onsite easy and quick calibration. Back to the office, you can then upload the data on a computer in order to issue customized calibration certificates with dedicated calibration software DATACAL.

IP 54, fully protected by an antichoc rubber holster, CALYS 150 integrates “easyconnect” terminals and a wide backlite display that makes it easy to use in any severe or dark conditions. When used with an external pressure module (ref. ACL433),CALYS 150 can measure and simulate pressure (comparison calibration with a pressure pump). CALYS 150 has also the capability to drive baths and dry-blocks when associated with the specific cable (ref. ACL600).

Easy connection system

Connect your probes by simply pushing on the terminal top and insert wires of up to 3 mm or 10 AWG diameter and compensated thermocouple connectors. Wires are held tight between two brass plates ensuring thermal stability and a very good cold junction compensation for thermocouples. This system also enables 4 mm banana plugs and security connectors to be connected on the terminal top.

Specification

Size 210 x 110 x 50 mm
Weight 900 g
Display 240 x 320 pixel liquid crystal graphical display with backlite and contrast control Display of result as table of values or trend curve
Power supply 230 V ± 10 %, 50/60 Hz
Battery Type:lithium-ion Charging Time:  3 hours lifetime: 8hours min
Communication ports USB
Storage capacity Up to 10 full configurations (Input / output type, range…) 10,000 data into one or several measurement campaigns, i.e. more than one week work with configurations, measurements, calibration procedures and reports
Reference range 23°C ± 5°C (RH: 45 to 75 % w/o condensing)
Operating reference range -10 to 50°C (RH: 20 to 80 % w/o condensing)
Limit operating range -15°C to +55°C (RH: 10 to 80 % w/o condensing) (70% at 55°C)
Storage temperature limits -30°C to +60°C
Maximum height 0 to 2000 m
IP protection IP54 according to EN60529
Protections • Electronic protection up to 250 V for ‘voltage’ wires
• Fuse protection for ‘current’ wires
• Protection against ‘current’ circuit breaking during inductive resistance measurements
Class In accordance with EN 61010-1 Category II, pollution 2
Rated voltage 60 V
Chocks and vibrations EN 61010-1
EMC conformity Immunity:
• EN 61000-4-2
• EN 61000-4-3
• EN 61000-4-5
• EN 61000-4-6
• EN 61000-4-11EN 61000-4-4 Conducted and radiated emissions:
• EN 55022, class B
• EN 61000-3-2
• EN 61000-3-3

Download

AOIP CALYS 150 Advanced documenting multifunction calibrator thermometer-DpstarGroup