Digital Scale Meter – Hanyoung Nux HP3

Features

  • High Accuracy indicator
  • Maximum display (-19999~19999)
  • Re-transmission
  • Communication function(select RS232 or RS485)
Enquiry

Digital Scale Meter
Model : HP3

  • High Accuracy indicator
  • Maximum display (-19999~19999)
  • Re-transmission
  • Communication function(select RS232 or RS485)

Specification

Power supply voltage 100 – 240 V a.c, 50 – 60 Hz (allowable voltage fluctuation : ±10 %)
Input Input contact : 1 Channel
Input specification : 4 – 20 mA, 1 – 5 V (Different input contact)
Accuracy : ±0.03 % of F.S
Sampling cycle : 500 ms
Input Compensation : -100 ~ 100 % of F.S, Input Filter : 0 ~ 100 s
Alarm output Output contact : 1C x 2 contacts (AL1, AL2)
Capacity of Contact : 5 A 240 V a.c, (5 A 30 V d.c)
Resolving power : 125 ms
Hysteresis : 0 ~ 10 % of F.S
Retransmission output Output contact : 1 contacts
Output range : 4 – 20 mA d.c
Load resistance : 600 Ω max
Accuracy : ±0.1 µA
Resolving power : 2,600
Insulation resistance 100 MΩ (500 V .d.c)
Dielectric strength 2300 V a.c, 50 Hz / 60 Hz for 1 min
Operating ambient Temperature : -5 ~ 50 ℃
Humidity : 20 ~ 90 % R.H. (With no condensation)
Storage ambient Temperature : -25 ~ 70 ℃
Humidity : 5 ~ 95 % R.H. (With no condensation)

Ordering Code

Model Code Information
HP3- Digital scalemeter
Optional 0 None
1 RS232
2 RS485