Flexible Signal Cable PVC Insulated With Blue Coloured PVC Sheath For EX-Zones – YSLY-EB

Features

  • For application in Ex-zones (with possible explosion danger), for equipment with independent supply source.
  • Lightweight and relatively thin, resistant to medium mechanical loads, used for fixed or limitedly mobile installations (not permanently mobile) without strains.
  • Laid in dry or damp premises, the outdoor application only under protection against UV irradiation.
  • Not intended for laying in ground or water.
Enquiry
Category:

Dpstar Group is your one-stop solution provider for Cables and Wires. We are the leading cable supplier in Malaysia, specializing in power cables, control instrument cables, Compensating Cables, and Heat Resistance Cables. As a leading control cable supplier, we have vast experience in advising on control cable selection. Our cables are supplied to meet the stringent standards of quality, performance, and functionality, with the ultimate goal of customer satisfaction.

The YSLY-EB Flexible Signal Cable for application in Ex-zones (with possible explosion danger), for equipment with independent supply source. Lightweight and relatively thin, resistant to medium mechanical loads, used for fixed or limitedly mobile installations (not permanently mobile) without strains. Laid in dry or damp premises, the outdoor application only under protection against UV irradiation. Not intended for laying in ground or water.

Specification

Construction
Conductor Bare copper conductor, fine wired stranded, class 5 acc. to IEC 60228 / HD 383 / DIN VDE 0295
Insulation PVC compound TI2 acc. to HD 21.1 / DIN VDE 0281 or YI2 acc. to VDE 0207.4, with green-yellow core, always in external layer (≥ 3 cores) or without green-yellow core
Core Marking (acc. to DIN VDE 0293) black numbered
Sheath PVC compound TM2 acc. to HD 21.1 / DIN VDE 0281 or YM2 acc. to VDE 0207.5
Sheath Colour Blue (RAL 5015)
Technical Data
Temperature Range
During Installation -5 °C up to +50 °C
Fixed Installed -30 °C up to +70 °C
Nominal Voltage Uo /U = 300/500 V
Test Voltage min. 4000 V
Insulation Resistance min. 20 MΩ x km
Min. Inner Bending Radius
Fixed Installed 4D
At Application With Bending 15D
Behaviour In Fire IEC 60332-1
Dimensions – Number of Cores x Conductor Cross-Section Construction Of Individual Conductor External Diameter Conductor Resistance at 20 °C Cu Weight Cable Weight  Packing*
N x mm² approx. mm approx. mm max. Ω/mm kg/km approx. kg/km
2 x 0.75 24 x 0.20 5.9 26 14.7 50 CUT
3 x 0.75 24 x 0.20 6.2 26 22.1 60 CUT
4 x 0.75 24 x 0.20 6.7 26 29.4 81 CUT
5 x 0.75 24 x 0.20 7.3 26 36.8 88 CUT
7 x 0.75 24 x 0.20 7.8 26 51.5 115 CUT
12 x 0.75 24 x 0.20 10.6 26 88.2 185 CUT
18 x 0.75 24 x 0.20 12.5 26 132.3 282 CUT
25 x 0.75 24 x 0.20 14.2 26 183.8 393 CUT
2 x 1 32 x 0.20 6.3 19.5 19.7 57 CUT
3 x 1 32 x 0.20 6.6 19.5 29.6 73 CUT
5 x 1 32 x 0.20 7.8 19.5 49.4 105 CUT
7 x 1 32 x 0.20 8.4 19.5 69.1 138 CUT
12 x 1 32 x 0.20 11.4 19.5 118.4 231 CUT
18 x 1 32 x 0.20 13.4 19.5 177.7 331 CUT
25 x 1 32 x 0.20 18.6 19.5 240 470 CUT
2 x 1.5 30 x 0.25 7.2 13.3 29 89 CUT
3 x 1.5 30 x 0.25 7.6 13.3 43 115 CUT
4 x 1.5 30 x 0.25 8.3 13.3 58 145 CUT
5 x 1.5 30 x 0.25 9.3 13.3 72 180 CUT
7 x 1.5 30 x 0.25 9.9 13.3 101 216 CUT
12 x 1.5 30 x 0.25 13.7 13.3 173 339 CUT
18 x 1.5 30 x 0.25 16.6 13.3 259 513 CUT
25 x 1.5 30 x 0.25 18.7 13.3 360 698 CUT

*Packing: CUT = cable in different lengths on drum or reel, possible cutting at required length

Download

YSLY-EB Flexible Signal Cable PVC Insulated With Blue Coloured PVC Sheath For EX-Zones-DpstarGroup