Fluoropolymer Insulated Constant Power Heating Cables – Flexelec FTTH – FTTH/T – FTTH/I – FTTH/TF – FTTH/IS

Features

  • Welded contact points.
  • Hard-wearing and flexible.
  • Can be cut to length on site.
  • Extremely simple termination.
  • Cold tail incorporated: no extra connection necessary.
  • Available as 20, 30, 40 or 50 W/m.
  • Power supply: 230 V as standard (400 V on request).
  • FTTH: fluoropolymer insulated constant power cables.
  • FTTH/T: with tinned copper braid for mechanical protection and earthing.
  • FTTH/I: with stainless steel braid for mechanical protection and earthing.
  • FTTH/TF: with tinned copper braid and fluoropolymer anti-corrosion outer sheath.
  • FTTH/IS: with stainless steel braid and silicone elastomer outer sheath.
Enquiry

Constant Wattage Heating Cables

Heat tracing applications are plentiful and various. Dpstar provides adapted solutions to heating cables used in various sectors such as construction, building, industry, and even the private sector. We offer you our experience of more than 30 years in supply and design of heating cables, heating tapes, heating cords with a complete range of accessories FLEXKIT. Dpstar provides serial heating cables, self-regulating heating cables, constant wattage heating cables, and many other heating elements to answer your needs. We understand your requirements and we are specialists in Electrical Heat Tracing solutions and provide reliable systems and solutions. Dpstar is responsible, trustworthy, and accountable you can count on.

The FTTH range is particularly suitable for maintaining temperatures of up to+ 150°C. Their fluoropolymer insulation endows them with the ability to withstand corrosive substances, making FTTH cables are particularly well-suited for use in the chemical industry. To ensure that these heating elements enjoy a long service life, we recommend using a control device.

Characteristics

  • Welded contact points.
  • Hard-wearing and flexible.
  • Can be cut to length on site.
  • Extremely simple termination.
  • Cold tail incorporated: no extra connection necessary.
  • Available as 20, 30, 40 or 50 W/m.
  • Power supply 230 V as standard (400 V on request).
  • FTTH: fluoropolymer insulated constant power cables.
  • FTTH/T: with tinned copper braid for mechanical protection and earthing.
  • FTTH/I: with stainless steel braid for mechanical protection and earthing.
  • FTTH/TF: with tinned copper braid and fluoropolymer anti-corrosion outer sheath.
  • FTTH/IS: with stainless steel braid and silicon elastomer outer sheath.
  • Special production on request.

Applications

  • Keep warm the food with heating tape.
  • Freeze protection of tunnel equipments with heating cables.
  • Temperature maintenance of bitumens with heater cables.
  • Keep process temperatures constant with heating cables in petrochemical.
  • Heat tracing of tanks and vessels with heating cables.

Specification

Model FTTH
Heating wire Nickel-Copper or Nickel-Chrome
Dimensions FTTH: 5 x 8 mm
FTTH/T – FTTH/I : 5.5 x 8.5 mm
FTTH/TF: 6 x 9 mm
FTTH/IS: 7 x 10 mm
Power 20, 30, 40 or 50 W/m
Permissible surface temperature from – 70°C to + 200°C
Ingress protection code IP54 with our kits
Min. bending radius 6 x the thickness of cable
Power Distance between 2 consecutive
contact points
Max. circuit length Max. maintenance
temperature
20 W/m 0.7 m 140 m 150°C
30 W/m 0.7 m 120 m 140°C
40 W/m 0.6 m 100 m 120°C
50 W/m 0.6 m 90 m 90°C