AOIP CP 6632 Handheld Process Signal Calibrator

Features

  • High precision: 0.015% of reading for an adjustable resolution of 1 mV and 1 µA
  • Display in A, mV and%
  • Low temperature coefficient: 15 ppm / ° C in voltage and 20 ppm / ° C in current
  • Active or passive loop power
  • Measurement with HOLD function
  • Simulation of ramps, preprogrammed steps, synthesizer values
  • Minimum, maximum and average display
  • Backlight
Enquiry

AOIP CP 6632 is a highly accurate process signal calibrator (150 ppm of reading) that measures and generates currents and voltages. It’s straightforward and durable, designed to make sensor and transmitter maintenance and commissioning easier using process signals like 4-20 mA or 0-10 V.

AOIP CP 6632 is suitable for various process tasks due to its scaling and specific calibrations. It can generate ramps, increments, and fixed values, useful for testing transmitters, indicators, and recorders in the process industry.

The temperature coefficients are very low: 15 ppm / ° C in voltage and 20 ppm / ° C in current. Precision is kept even in difficult temperature conditions, on site for example. As standard CPs are delivered with 4 AA type batteries. With the battery charger option, users can recharge the battery pack directly from the mains.

Specification

Dimensions L x W x H 157 x 85 x 45 mm
Mass 306 g
Screen 160 x 160 pixel graphic LCD display with backlight
Display of measurements in table form or trend line
Food 4 AA 1.5 V batteries or rechargeable Ni-Mh battery with optional built-in charger
Autonomy:
> 53 h in voltage and current measurement and voltage simulation
> 12 h in current simulation
Communication interfaces USB
Reference area 23 ° C ± 5 ° C (RH: 45 to 75% non-condensing)
Nominal operating range -10 to 50 ° C (RH: 20 to 80% non-condensing)
Operating limit range -15 to 55 ° C (RH: 10 to 80% non-condensing) (70% at 55 ° C)
Storage conditions -30 ° C to + 60 ° C
Operating altitude 0 to 2200 m
Protection sign IP54 according to EN60529
Protections • Electronics: Up to 250 V on ‘voltage’ wires
• By fuse on the ‘current’ wires
• Against the opening of the ‘current’ circuit in measurement of inductive resistances
Classroom Complies with European standard EN 61010-1
Category II, pollution 2
Assignment voltage with respect to earth 60 V
Shock and vibration resistance EN 61010-1
EMC compliance Immunity:
• Electrostatic discharges: EN 61000-4-2
• Radiated fields: EN 61000-4-3
• Shock waves: EN 61000-4-5
• Conducted disturbances: EN 61000-4-6
• Voltage dip: EN 61000-4-11
• Salvo: EN 61000-4-4Radiated emission and conduct:
• EN 55022, class B
• EN 61000-3-2
• EN 61000-3-3