AOIP PHP 602 High Accurate Dual Input Reference Thermometer For RTDs

Features

  • Temperature measurements using RTDs
  • Absolute or differential measurements over two channels
  • Differential thermal analysis
  • Checking the temperature stability of furnaces or baths
    • Monitoring (alarm) and temperature recording
Enquiry

AOIP PHP 602 is a highly accurate thermometer with dual inputs for resistive probes. It already contains a large database of probe information. In addition, users can create new linearization tables at any time, and all metrological parameters, including corrections against standards, serial numbers, names, and calibration dates, are stored in the memory. When paired with VISULOG data management software, AOIP CALYS 100 can control PHP thermometers and thermal devices like temperature baths, dry block calibrators, or ovens. This allows for complete calibration procedures, report generation, and printing certificates for each sensor.

The graphical dual display of AOIP CALYS 100 shows measurements from both channel 1 and 2 at the same time, making the keyboard easier to use. Users can access on-line help messages anytime for extra guidance on displayed options. It’s fully programmable through RS 232 and IEEE 488 interfaces (optional), making it ideal for test benches and automatic test equipment setups. PHP 601 comes with an optional battery. PHP 602 is available in a compact benchtop design for on-site, benchtop, or panel-mounted use. It is widely used in metrological departments, quality control, research labs, and maintenance and certification companies.

Specification

Size 225 x 88 x 310
Weight 2 to 3 kg according to the configuration
Display Graphical back-lit LCD display, 600,000 counts
Power supply 115 / 230 V ± 10%, 50/400 Hz
Battery (option) Type: 12 V
Battery life: 2 to 3.5 hours
Charging time: 12 to 14 hours
Communication ports RS 232
IEEE488 in option
Storage capacity 5,000 measurements in one burst or up to 128 bursts of one measurement. Bursts are tagged with an item number and can be identified with a label.
Reference range 23°C ± 1°C (RH: 45 to 75 % w/o condensing)
Operating reference range 0 to 50°C (RH: 20 to 75 % w/o condensing)
Limit operating range -10°C to +55°C (RH: 10 to 80 % w/o condensing)
Storage temperature limits -30°C to +55°C (-15 to +50°C for model with battery charged)
Maximum height 2500 m
IP protection IP40 according to EN60529
Class In accordance with EN 61010-1
Category III, pollution 2
Rated voltage 60 V
Chocks and vibrations EN 61010-1
EMC conformity Immunity:
• EN 61000-4-2
• EN 61000-4-3
• EN 61000-4-5
• EN 61000-4-6
• EN 61000-4-11EN 61000-4-4
Conducted and radiated emissions:
• EN 55022, class B
• EN 61000-3-2
• EN 61000-3-3