RTD Temperature Converter – Shimaden CP3702 Series

Features

  • Slim-shaped plug-in converter with isolated single/dual- output
  • DIN Rail mounting or Lateral mounting
  • Power supply 100 – 240V AC or 24V DC
  • Moisture-proof coating is applied as standard.
  • CE marking applied (applicable standard: EMC: EN61326-1)
Enquiry

This Slim-shaped Plug-in R.T.D temperature converter, CP3702 functions to convert input from RTD into standard process signal to generate isolated dual output.

Specification

Input R.T.D. Pt100/JPt100
Conversion accuracy Within ±0.15% at 25±5°C
Effection against ambient temperature ±0.2% max. against span of 10°C temperature difference
Measuring range See measuring range code
Amperage 1mA
Input lead wire resistance 200Ωmax./wire
Maximum output load DC voltage: 1V span min. Load current:2mA max.
10mV span min. Load resistance: 10kΩmin.
100mV span min. Load resistance: 100kΩmin.
DC current: 4-20mA Single output: Load current: 750Ωmax.
4-20mA Dual output: Output 1: 550Ωmax.
Output 2: 350Ωmax.
Input resistance 1MΩmin. (1MΩ when power failure/constant input)
External resistance tolerance range 1kΩ max.
Response speed 170m sec. max. (0-90%) at 100% step input
Burnout up-scale
Conversion output variable range zero:   Approx. ±5%FS of span (adjustable by front trimmer)
span: Approx. ±5%FS of span (adjustable by front trimmer)
Power supply 100 – 240V AC ±10% or 24V DC±10%
Power consumption 2W max. at 24V DC
Operating ambient temperature -5 – 55°C
Operating ambient humidity 5 – 90%RH (No dew condensation)
Stock temperature -10 – 60°C
Isolation resistance 100M Ω min. at 500V DC, between input, out 1, out 2, power supply and ground terminals
Dielectric strength 1 minutes at 2000V AC, between input, out 1, out 2, power supply and ground terminals
1 minutes at 500V AC, between out 1 and out 2
Materials: Housing: ABS resin (UL94V-0)
Terminal block: PBT resin (UL94V-0)
Terminal block cover: PC resin (UL94V-2)
Din-rail stopper: PP resin (UL94-HB)
External dimensions 88 (H) x 29 (W) x D125 (H)mm
Weight Main body: 120g max.
Terminal block: 80g max.

Ordering Information

ITEMS CODE SPECIFICATIONS
Series CP3702- R.T.D. Temperature Converter
Output 1 1 0 – 10mV DC
2 0 – 100mV DC
3 -10 – 10mV DC
4 -100 – 100mV DC
5 1 – 5V DC
6 4 – 20mA DC
7 0 – 5V DC
8 0 – 10V DC
9 Others (Please consult before ordering.)
Output 2 0 None
1 0 – 10mV DC
2 0 – 100mV DC
3 -10 – 10mV DC
4 -100 – 100mV DC
5 1 – 5V DC
6 4 – 20mA DC * Note: Available only when output 1 (4 – 20mA DC) is selected.
7 0 – 5V DC
8 0 – 10V DC
9 Others (Please consult before ordering.)
Power Supply 90- 100 – 240V AC ±10% 50/60Hz
08- 24V DC ±10%
Input F Pt100
J JPt100
Measuring Range °°° See measuring range codes.
Remarks 0 Without
9 With (Please consult before ordering.)

Download