Series Cables For Underfloor Heating – Flexelec KYCYR

Features

  • Hard-wearing and flexible.
  • Mechanical protection and earthing.
  • 3 m power cable on one end only, integrated return conductor.
  • Power supply: 230 V as standard.
  • Series resistance, silicon elastomer, and PVC insulation, with copper braided shielding and an extra PVC outer sheath.
Enquiry

Through our deep knowledge and experience, we are able to supply electrical heat tracing systems and solutions to achieve both dynamic heat up and temperature maintenance applications in Oil and Gas, Palm Oil, Food Industry, and others. We understand your requirements and we are specialists in Electrical Heat Tracing solutions and provide reliable systems and solutions. Dpstar is responsible, trustworthy, and accountable you can count on.

Underfloor Heating Cables, Electric Underfloor Heating 

FLEXFLOOR heating cables permit floor heating of the inside and outside. These heating cables are particularly hard-wearing and are used for applications set in concrete slabs (KYCY and KYCYR).

KYCYR heating cables are particularly hard-wearing and are used for applications set in concrete slabs to protect against freezing or to maintain a temperature. The cables must be set in accordance with the local regulations in force. To ensure that these heating elements enjoy a long service life, we recommend using a control device.

Characteristics

  • Hard-wearing and flexible.
  • For mechanical protection and earthing.
  • 3 m power cable on one end only, integrated return conductor.
  • Power supply: 230 V as standard.
  • Series resistance, silicon elastomer, and PVC insulation, with copper braided shielding and an extra PVC outer sheath.
  • Special production on request.
  • Ingress protection code: IP65 terminated cable by ourself, -IK08.


Applications

  • Force seedlings with a heating cable.
  • Heating of landing areas or walkways with heating cables.
  • Prevent mist, ice or frost forming with heating cable.
  • Stop snow and ice in gutters with heating cables. Stop snow and ice in gutters with heating cables.
  • Prevent ice from forming on the floor with a heating cable.
  • Keep accesses free of ice with heating cables.
  • Maintain the temperature of concrete sub-bases.
  • Avoid damages on floor skating rinks with heating cables.
  • Stadium heating with heating cables.
  • Floor heating with heating cable.

Specification

Model KYCYR
Heating strand Heavy-duty strand or coiled heating wire (Nickel-Copper or Nickel-Chrome)
Diameter 7 to 8 mm
Max. power 27 W/m
Permissible surface temperature up to + 80°C
Min. bending radius 6 x the diameter
Tolerance Resistance : – 5% / + 10%
Length ± 1 %

Standard 230 V models

27 W/m freeze protection
Length (m) Power (W) Resistance (Ω/m)
8.5 230 27.0
11 300 16.0
13 350 11.8
17 460 6.7
26 720 2.8
34 930 1.7
41 1100 1.2
47 1260 0.87
63 1700 0.47
78 2100 0.30
94 2530 0.20
110 2970 0.16
122 3290 0.13
20 W/m
Length (m) Power (W) Resistance (Ω/m)
10 200 27.0
15 300 11.8
20 400 6.7
30 600 2.8
40 800 1.65
48 940 1.15
55 1100 0.87
75 1500 0.47
90 1800 0.30
113 2100 0.20
10 W/m
Length (m) Power (W) Resistance (Ω/m)
13 100 41.0
14 140 27.0
15.5 206 16.0
18 180 16.0
20 160 16.0
20 285 9.2
21 210 11.8
24 240 9.2
28 280 6.7
36 360 4.0
44 430 2.8
49 480 2.24
57 560 1.65
68 660 1.15
78 780 0.87
92 920 0.6
104 1040 0.47
128 1280 0.3
155 1550 0.2