Silicon Insulated Drain-line Heater Cables Single Insulation – Flexelec CSC – CSC/T – CSC/I – CSC/TS

Features

  • Fully sealed.
  • Extremely flexible.
  • Any voltage on request up to 500V.
  • Power cable: standard length 1 m.
  • CSC: silicon elastomer insulated drain-line heaters cables.
  • CSC/T: silicon elastomer insulated drain-line heaters cables with tinned copper braid for earthing and mechanical protection.
  • CSC/I: silicon elastomer insulated drain-line heaters cables with stainless steel braid for earthing and mechanical protection.
  • CSC/TS: silicon elastomer insulated drain-line heaters cables with tinned copper braid for earthing and silicon elastomer insulated.
Enquiry

Through our deep knowledge and experience, we are able to supply electrical heat tracing systems and solutions to achieve both dynamic heat up and temperature maintenance applications in Oil and Gas, Palm Oil, Food Industry, and others. To maintain a static or a moving product at an even temperature, Dpstar provides a wide range of heating cables. We understand your requirements and we are specialists in Electrical Heat Tracing solutions and provide reliable systems and solutions. Dpstar is responsible, trustworthy, and accountable you can count on.

FLEXDRAIN drain-line heaters include a heating part and a cold power cable at one end. These drain-line heaters are used in the refrigeration industry for freeze protection of drain pipes and for condensate in the drain pan. Extremely flexible, these drain heating cables are quick, safe and easy to use. Standard sizes or designs as requested these heater cables solve many of the problems in the installation you may be faced with.

CSC, CSC/T, CSC/I, and CSC/TS heaters cables are designed to be laid inside pipes for draining water from thawing refrigeration equipment installed in cold rooms. They operate only during thawing cycles. To ensure that these heating elements enjoy a long service life, we recommend using a control device.

Characteristics

  • Fully sealed.
  • Extremely flexible.
  • Any voltage on request.
  • Power cable: standard length: 1m.
  • CSC: silicon elastomer insulated drain-line heaters.
  • CSC/T: with tinned copper braid for earthing and mechanical protection.
  • CSC/I: with stainless steel braid for earthing and mechanical protection.
  • CSC/TS: with tinned copper braid and silicon elastomer insulated.
  • Special production on request.

Applications

  • Protect fluids against ice on refrigerated systems with heating cables.
  • Temperature maintenance of fluids with the heating element.
  • Allow water from defrost cycles to flow of the evaporators with heating cables.
  • Heating cables for terrariums and aquariums.
  • Allow water from defrost cycles to flow using heating cables.
  • Prevent ice from forming of the drain pan with heating cable.
  • Supply drinking water to animals, studs, and farms, both inside unheated buildings and in fields. Electrical trace heating must be used in conjunction with electrical and mechanical protection to ensure safety for the animals

Specification

Model CSC CSC/T – CSC/I – CSC/TS
Heating wire Nickel-Copper or Nickel-Chrome
Diameter 5.7 mm 6 mm
Max. power 50 W/m
Voltage Any voltage on request up to 500 V
Permissible surface
temperature
from – 70°C to + 200°C
Tolerances Power : ± 10 %
Diameter : + 0.2 / – 0.1 mm
Length : ± 1 %
End insulation Sealed silicon moulding
Ingress protection code IP66
Minimum bending radius 6 x the diameter
Insulation Class CLASS 0 (single insulated)
CLASS III (if low Voltage)
CLASS I (earthing)