Ninomiya Fiber Glass 2-Pair (Round Type) – Thermocouple Extension Cables

Features

4 (2 pairs) elemental compensating wires are served and braided with glass-yarn separately to be insulated, stranded together after stranded in pairs, shielded with tin-coated annealed copper wires (B), braided with glass-yarn, and braided with stainless wires (C) for protection at the outermost.

Enquiry

Ninomiya Fiber Glass 2-Pair (Round Type) – Thermocouple Extension Cables

4 pairs of elemental compensating wires are individually insulated, stranded in pairs, shielded with tin-coated annealed copper wires (B), and braided with glass yarn. Finally, they are further protected with an outermost layer of stainless steel wire (C).

Specification

Parts No. Construction No. of pairs Conductor Insulation OD of pair mm OD of cabling mm Shield
thickness
mm
Sheath
thickness
mm
Finished
OD
mm
Standing
No./mm
OD
mm
Thickness
mm
OD
mm
12/0.18x2P □X-H=GBT A 2 12/0.18 0.7 0.4 1.5 3.6 0.3 4.2
12/0.18x2P □X-H-IS=GBT B 2 12/0.18 0.7 0.4 1.5 3.6 0.3 0.3 4.8
12/0.18x2P □X-H-SOS=GBT C 2 12/0.18 0.7 0.4 1.5 3.6 0.3 0.3 4.8
7/0.3x2P □X-H=GBT A 2 7/0.3 0.9 0.4 1.7 4.1 0.3 4.7
7/0.3x2P □X-H-IS=GBT B 2 7/0.3 0.9 0.4 1.7 4.1 0.3 0.3 5.3
7/0.3x2P □X-H-SOS=GBT C 2 7/0.3 0.9 0.4 1.7 4.1 0.3 0.3 5.3
20/0.18x2P □X-H=GBT A 2 20/0.18 1 0.4 1.8 4.3 0.3 4.9
20/0.18x2P □X-H-IS=GBT B 2 20/0.18 1 0.4 1.8 4.3 0.3 0.3 5.5
20/0.18x2P □X-H-SOS=GBT C 2 20/0.18 1 0.4 1.8 4.3 0.3 0.3 5.5
30/0.18x2P □X-H=GBT A 2 30/0.18 1.2 0.4 2 4.8 0.3 5.4
30/0.18x2P □X-H-IS=GBT B 2 30/0.18 1.2 0.4 2 4.8 0.3 0.3 6
30/0.18x2P □X-H-SOS=GBT C 2 30/0.18 1.2 0.4 2 4.8 0.3 0.3 6
7/0.45x2P □X-H=GBT A 2 7/0.45 1.35 0.4 2.15 5.2 0.35 5.9
7/0.45x2P □X-H-IS=GBT B 2 7/0.45 1.35 0.4 2.15 5.2 0.3 0.35 6.5
7/0.45x2P □X-H-SOS=GBT C 2 7/0.45 1.35 0.4 2.15 5.2 0.35 0.3 6.5
4/0.65x2P □X-H=GBT A 2 4/0.65 1.57 0.4 2.37 5.7 0.35 6.4
4/0.65x2P □X-H-IS=GBT B 2 4/0.65 1.57 0.4 2.37 5.7 0.3 0.35 7
4/0.65x2P □X-H-SOS=GBT C 2 4/0.65 1.57 0.4 2.37 5.7 0.35 0.3 7
7/0.65x2P □X-H=GBT A 2 7/0.65 1.95 0.4 2.75 6.6 0.35 7.3
7/0.65x2P □X-H-IS=GBT B 2 7/0.65 1.95 0.4 2.75 6.6 0.3 0.35 7.9
7/0.65x2P □X-H-SOS=GBT C 2 7/0.65 1.95 0.4 2.75 6.6 0.35 0.3 7.9

Please fill in □ with a type (symbol) of a compensating cable to order.
We also manufacture outer shields for tin-coated annealed copper wires (OS) and for stainless wires (SOS). Please contact us with any requests.
Ninomiya Standard 2-pair compensating cables are basically stranded totally. If you need twin stranded cables, please notice it when you order.

Download