Vaisala DL4000 Universal Data Loggers

Features

  • 10-year battery and large onboard memory
  • Single and multi-channel models with up to four input channels
  • Easily set scaling and measurement units for recording
  • Time-based digital recording in a range of sample intervals
  • Multiple connectivity options – USB, Ethernet, WiFi
  • Optional vNet cradle for Ethernet or Power over Ethernet connectivity
  • Traceable to SI units through national metrology institutes.
  • Two-year limited warranty
Enquiry

Vaisala DL4000 Universal Data Loggers can connect to various sensors and transmitters that use DC voltage or 0-20 mA current loop output. They’re simple solution for recording pressure, flow, fluid level, PH, electrical properties, moisture, and gas concentrations. Ideal for use in standalone or in networks. Vaisala DL4000 can connect directly to your PC via USB or to a network using Ethernet, Power over Ethernet, or WiFi. Each logger has a 10-year battery and onboard memory for recording data right at the measurement point. With autonomous power and recording capacity, data is immune to network and power interruptions.

Vaisala DL4000 data loggers work with two Vaisala software options: viewLinc for continuous monitoring and vLog for validation and mapping. With viewLinc, you get 24/7 alarm notifications, real-time monitoring, and complete data. vLog is perfect for validation and mapping tasks. DL4000 data loggers are calibrated to meet strict standards and provide customizable reports that can be exported to spreadsheets and PDFs, meeting regulatory requirements. Choose DL4000 VL series for regulated environments and DL4000 SP series for non-regulated applications.

2) Measurement results are traceable to the international system of units (SI) through national metrology institutes (NIST USA, MIKES Finland, or equivalent) or ISO/IEC 17025 accredited calibration laboratories.

Key Benefits

  • Easy to set up and use
    Vaisala DL4000 data loggers can be used with Vaisala continuous monitoring system software viewLinc for monitoring and analyzing environmental data. Vaisala’s OPC Server software can also be used to integrate Vaisala DL4000 data loggers with non-Vaisala systems.
  • Onboard battery and autonomous memory
    Data is recorded at the point of measurement making it immune to network and power interruptions. With typical battery life of ten years and large onboard memory, Vaisala DL4000 is a reliable solution for logging multiple parameters with a single device. Remote alarming ensures you know when thresholds are breached.
  • Flexible connectivity options
    To access Vaisala DL4000 data, connect directly via USB, or a network via Ethernet, Wi-Fi, or use Vaisala’s vNet interface for Power over Ethernet connectivity.

Dpstar is a leading supplier of environmental measurement sensors for temperature, relative humidity, pressure, dew point, CO2, and other environmental condition monitoring for industrial process application and research. Since the ’90s, we earned a reputation as a trusted partner to our clients through our commitment and dedication. We are an authorized distributor and supplier of measuring sensors solutions from renowned manufacturers Vaisala. Vaisala is a global leader in environmental and industrial measurement. Building on 80 years of experience, Vaisala provides observations for a better world. Vaisala is a reliable partner for customers around the world, offering a comprehensive range of innovative observation and measurement products and services.

Specification

General specifications
Operating range −40 … +85 °C (−40 … +185 °F) and 0 … 100 %RH (non-condensing)
Interfaces RS-232 serial
USB
Wifi module
Ethernet and Power over Ethernet
(vNet)
Weight 76 g (2.7 oz)
Size 85 × 59 × 26 mm (3.4 × 2.3 × 1 in)
Mounting 3M Dual Lock™ fasteners
PC software Graphing & Reporting Software
vLog SP for SP-series
vLog VL for VL-series
viewLinc for continuous monitoring & alarming
OPC Server to add on to existing OPC
compatible monitoring systems
Internal clock Accuracy ±1 min/month at −25 … +70 °C (−13 … +158 °F)
Electromagnetic compatibility FCC Part 15 and CE
EN 50581:2012
EN 55032:2012/AC:2013 Class B
EN 61326-1:2013
RoHS compliance 2011/65/EU
Power source Internal 10-year lithium battery (Battery life specified with sample interval of 1 min or longer)
Memory Specifications
Memory type Non-volatile EEPROM
Data sample capacity 120 000 12-bit samples
Memory modes User-selectable wrap (FIFO) or stop when memory is full. User-selectable start and stop times.
Sampling rates User-selectable from once every 10 seconds to once a day. (Battery life specified with sample interval of 1 min or longer)
Recording span Recording span depends upon sample interval selected and number of channels enabled. Please see table above.
Recording Span
1 2 3 4
10 seconds 13.8 days 6.9 days 4.6 days 3.4 days
1 minute 2.7 months 1.3 months 27.7 days 20.8 days
5 minutes 1.1 years 6.9 months 4.6 months 3.4 months
15 minutes 3.4 years 1.7 years 1.1 years 10.4 months
1 hour 13.6 years 6.8 years 4.5 years 3.4 years
Current Loop & Voltage Inputs
Available ranges 0 … 20mA 0 … 5 VDC, 0 … 10 VDC
Resolution 5.5 μA 0.025 % F.S.
Accuracy ±0.15 % F.S. at +25 °C
(+77 °F)
±0.15 % F.S. at +25 °C
(+77 °F)
Input impedances 75 Ω > 1 MΩ
Isolation One common per logger One common per logger
Overload protection 40 mA max. (reverse polarity protected) ±24 VDC max. (reverse polarity protected)
Channel configurations
4000-405 0 … 5 VDC
4000-40A 0 … 10 VDC
4000-40C 0 … 20 mA

Download

Vaisala DL4000 Universal Data Loggers_DpstarGroup