Vaisala PTB210 Digital Barometer

Features

  • Different scalings between 500 … 1100 hPa with analog output
  • 500 … 1100 hPa or 50 … 1100 hPa pressure ranges with serial output
  • Electronics housing IP65 protected against sprayed water
  • Traceable calibration (certificate included)
  • Accurate and stable measurement
Enquiry

Dpstar is a leading supplier of environmental measurement sensors for temperature, relative humidity, pressure, dew point, CO2, and other environmental condition monitoring for industrial process application and research. Since the ’90s, we earned a reputation as a trusted partner to our clients through our commitment and dedication. We are an authorized distributor and supplier of measuring sensors solutions from renowned manufacturers Vaisala. Vaisala is a global leader in environmental and industrial measurement. Building on 80 years of experience, Vaisala provides observations for a better world. Vaisala is a reliable partner for customers around the world, offering a comprehensive range of innovative observation and measurement products and services.

Vaisala PTB210 Digital Barometer is excellent solution for outdoor installations and harsh environments. PTB210 is designed to operate in a wide temperature range, and the electronics housing provides IP65 (NEMA 4) standardized protection against sprayed water. PTB210 is ideal for use in applications such as weather stations, data buoys, ships, airports, and agrology. It is also an excellent solution for monitoring barometric pressure in industrial equipment such as laser interferometers and engine test benches.

Dimension

Key Benefits

For Harsh Environments
The PTB210 is ideal for outdoor installations and harsh environments. Operate in a wide temperature range, and the electronics housing provides IP65 (NEMA 4) standardized protection against sprayed water.

Excellent Hysteresis & Repeatability Characteristics
The PTB210 barometers use the Vaisala BAROCAP® Sensor, a silicon capacitive absolute pressure sensor developed by Vaisala for barometric pressure applications.

Several Pressure Ranges
The PTB210 barometers are designed for various pressure ranges. They are available in two basic configurations: serial output for 500 … 1100 hPa and 50 … 1100 hPa and analog output with different scalings between 500 … 1100 hPa.

Specification

Measurement Performance
Pressure range
Serial output 500 … 1100 hPa
50 … 1100 hPa
Analog output 500 … 1100 hPa
600 … 1060 hPa
800 … 1060 hPa
900 … 1100 hPa
Analog Output, Accuracy
Non-linearity 1) ± 0.20 hPa
Hysteresis 1) ± 0.05 hPa
Repeatability 1) ± 0.05 hPa
Calibration uncertainty 2) ± 0.15 hPa
Accuracy at +20 °C (+68 °F) 3) ± 0.30 hPa
Temperature dependency 4) ± 0.50 hPa
Total accuracy -40 … +60 °C (-40 … +140 °F) 3) ± 0.60 hPa
Long-term stability ± 0.10 hPa/year
1) Defined as the ±2 standard deviation limits of end point non-linearity, hysteresis error, or repeatability error.
2) Defined as ±2 standard deviation limits of inaccuracy of the working standard including traceability to international standards.
3) Defined as the root sum of the squares (RSS) of end point non-linearity, hysteresis error, repeatability error, and calibration uncertainty at room temperature.
4) Defined as ±2 standard deviation limits of temperature dependence over the operating temperature range.
Operating Environment
Operating temperature −40 … +60 °C (−40 … +140 °F)
Operating humidity 0 … 100 %RH, non‑condensing
Compliance
Directives EMC Directive (2014/30/EU)
RoHS Directive (2011/65/EU)
EMC compatibility EN / IEC 61326-1, Electrical equipment for measurement, control and laboratory use – EMC requirement; Basic environment CISPR 32 / EN 55032, Class B
Compliance CE, FCC, UKCA
Mechanical Specifications
Housing material PC plastic
IP rating, electronics IP65 (NEMA 4)
IP rating, sensor IP53
Weight, sensor 110 g (3.9 oz)
Cable weight 28 g/m (1.0 oz)
Inputs and Outputs
Serial Output
Shutdown ON/OFF
Settling time at startup 2 s
Serial I/O RS-232C
RS-232C / TTL (optional)
RS-485, non-isolated (optional)
Parity None, even, odd
Data bits 7, 8
Stop bits 1, 2
Baud rate 1200, 2400, 4800, 9600, 19200
Response time1 1 s
Resolution 0.01 hPa (1 measurement/s)
0.03 hPa (10 measurements/s)
Current consumption, normal mode < 15 mA (factory setting)
Current consumption, shutdown mode 0.2 mA
Analog output
Outputs 0 … 5 V DC, 0 … 2.5 V DC (order specified)
Shutdown ON/OFF
Response time 500 ms
Resolution 300 μV
Measurement rate 3 measurements/s
Current consumption, normal mode < 8 mA
Current consumption, shutdown mode 0.2 mA
All models
Max. pressure 5 000 hPa absolute
Pressure connector M5 (10-32) internal thread
Pressure fitting Barbed fitting for 1/8 in I.D. tubing
Supply voltage (reverse polarity protected), with RS-232/TTL output 5 … 28 V DC
Supply voltage (reverse polarity protected), with RS-485 or analog output 8 … 18 V DC
Serial output, accuracy (hPa)
Pressure range 500 … 1100 50 … 1100
Class Class A Class B
Non-linearity 1) ± 0.10 ± 0.15 ± 0.20
Hysteresis 1) ± 0.05 ± 0.15 ± 0.10
Repeatability 1) ± 0.05 ± 0.05 ± 0.11
Calibration uncertainty 2) ± 0.07 ± 0.15 ± 0.20
Accuracy at +20 °C (+68 °F) 3) ± 0.15 ± 0.20 ± 0.35
Temperature dependency 4) ± 0.20 ± 0.20 ± 0.40
Total accuracy-40 … +60 °C (-40 … +140 °F) 3) ± 0.25 ± 0.30 ± 0.50
Long-term stability (hPa/ year) ± 0.10 ± 0.10 ± 0.20

Download