Vaisala HMP110 Humidity and Temperature Probe

Features

  • Miniature-size humidity transmitter.
  • Low power consumption and fast start-up for battery-powered applications.
  • Measurement range: 0 … 100 %RH; −40 … +80 °C (−40 … +176 °F)
  • Cable detachable with standard M8 quick connector
  • IP65 metal housing
  • Optional RS-485 digital output supports Modbusâ RTU
  • ±1.5 %RH measurement accuracy (0 … 90 %RH)
  • Temperature-only model HMP110T also available
Enquiry
Category:

Dpstar is a leader in environmental and industrial measurements. Curiosity and innovation are core values in our company. Our extensive knowledge and expertise are materialized in our selection of innovative products. Accurate measurements are essential for healthy indoor air and improving the energy efficiency of buildings. The unique, cutting-edge Dpstar sensor technologies are manifested throughout our versatile range of products. The transmitters have an exceptionally long lifetime and excellent measurement stability, thus being practically maintenance-free. These are among the many reasons why Dpstar’s products are a sustainable choice.

The HUMICAP Humidity and Temperature Probe HMP110 is a trouble-free and cost-effective humidity transmitter with high accuracy and good stability. The power consumption is low and it has a fast startup for battery-powered applications. A rugged polyurethane-filled stainless steel body survives also in rough conditions. All models come with a calibration certificate. This probe is suitable for volume applications or integration into other manufacturers’ equipment and also for glove boxes, greenhouses, fermentation and stability chambers, data loggers, and incubators.

Three models are available:

  • Humidity and temperature probe
  • Temperature only probe with an RS485 interface supporting Modbus RTU protocol
  • Temperature only probe with voltage outputs

The miniature size HMP110 has a measurement range of 0 … 100 %RH; -40 … +80°C and the probe incorporates the latest generation HUMICAP 180R sensor for best stability and high chemical tolerance. The HMP110 has an IP65-classified metal housing.

Dimension

   

Benefits

  • Easy Installation
    The probe cable has a screw-on quick connector for easy installation. Different cable lengths and accessories are available.
  • Low current consumption
    HMP110 is suitable for battery-powered applications because of its very low current consumption. It also has a fast start-up time.
  • Several Outputs
    Temperature measurement is a standard feature in the HMP110, with dew point temperature, wet bulb temperature, absolute humidity, mixing ratio, and enthalpy as optional calculated parameters. Three standard voltage outputs are available. An optional RS-485 output with Modbus support is also available.
  • Robust Design
    The stainless steel body of HMP110 is classified as IP65, making it ideal for rough conditions. HMP110 has high chemical tolerance thanks to the
    HUMICAP 180R sensor.
  • Easy Maintenance
    Maintaining measurement traceability is easy using the HMP110R replacement probe. We send you a replacement probe, you detach the old probe and send it back to us. This way the measurement is available at all times without interruptions.

Applications

HMP110 is a trouble-free and cost-e€ective humidity transmitter with high accuracy and good stability. It is suitable for volume applications or integration into other manufacturers’ equipment. HMP110 is also suitable for glove boxes, greenhouses, fermentation and stability chambers, data loggers, and incubators.

Specification

Models
Model Output Special features
HMP110 RH+T
HMP110T T
HMP110R RH+T Replacement probe for HMP110
HMP110REF Fixed output probe for validation of HMT120 and HMT130 transmitters
Relative humidity
Measurement range 0 … 100 %RH
Accuracy (1) (2) at 0 … +40 °C (+32 … +104 °F) ±1.5 %RH (0 … 90 %RH)
±2.5 %RH (90 … 100 %RH)
at −40 … 0 °C (−40 … +32 °F) and
+40 … +80 °C (+104 … +176 °F)
±3.0 %RH (0 … 90 %RH)
±4.0 %RH (90 … 100 %RH)
Factory calibration uncertainty
at +20 °C (+68 °F)
±1.1 %RH (0 … 90 %RH)
±1.8 %RH (90 … 100 %RH)
Humidity sensor types HUMICAPâ 180R
HUMICAPâ 180V
Stability ±2 %RH over 2 years
Temperature
Measurement range −40 … +80 °C (−40 … +176 °F)
Accuracy (probes with analog output) at 0 … +40 °C (+32 … +104 °F) ±0.2 °C (±0.36 °F)
at −40 … 0 °C (−40 … +32 °F) and
+40 … +80 °C (+104 … +176 °F)
±0.4 °C (±0.72 °F)
Accuracy (probes with digital output) at +15 … +25 °C (+59 … +77 °F) ±0.1 °C (±0.18 °F)
at 0 … +15 °C (+ 32 … +59 °F) and
+25 … +40 °C (+77 … +104 °F)
±0.15 °C (±0.27 °F)
at −40 … 0 °C (−40 … +32 °F) and
+40 … +80 °C (+104 … +176 °F)
±0.4 °C (±0.72 °F)
Temperature sensor Pt1000 RTD Class F0.1 IEC 60751
Analog outputs
Accuracy at +20 °C (+68 °F) ±0.2 % of FS
Temperature dependence ±0.01 % of FS/°C (±0.006 % of FS/°F)
(1) Including non-linearity, hysteresis, and repeatability.
(2) With HUMICAPâ 180V sensor, accuracy is not specified below −20 °C (−4 °F) operating temperature.
Operating environment
Operating temperature −40 … +80 °C (−40 … +176 °F)
EMC compliance EN 61326-1, industrial environment
Inputs and outputs
Power consumption 1 mA average, max. peak 5 mA
Operating voltage (1)
With 1 V / 2.5 V output 5 … 28 VDC
With 5 V output 8 … 28 VDC
With loop power converter 8 … 28 VDC
With digital output 5 … 28 VDC
Start-up time
HMP110 probes with analog output 4 s at operating voltage
13.5 … 16.5 VDC
2 s at other valid operating voltages
HMP110 probes with digital output 1 s
Outputs
2 channels 0 … 1 VDC / 0 … 2.5 VDC / 0 … 5 VDC / 1 … 5 VDC
1-channel loop-power converter (separate module, compatible with humidity accuracy only) 4 … 20 mA
Digital output (HMP110 probes with digital output) RS-485 2-wire half duplex, supports Modbus RTU
External loads
0 … 1 V RL min 10 kΩ
0 … 2.5 V /0 … 5 V RL min 50 kΩ
Output parameters
Relative humidity, temperature, dew point temperature, wet bulb temperature, absolute humidity, mixing ratio, enthalpy
(1) Use lowest available operating voltage to minimize heating.
Mechanical 
IP rating IP65 (1)
Body thread MI2x1 / 10 mm (0.4 in)
Cable connector M8 4-pin female (IEC 60947-5-2)
Materials
Body Stainless steel (AISI 316)
Grid filter Chrome coated ABS plastic
Cable Polyurethane or FEP
Weight
Probe 17 g (0.6 oz)
Probe with 0.3 m (1 ft) cable 28 g (1 oz)
(1) Applicable with stainless steel sintered filter and PTFE sintered filter only
Spare Parts & Accessories
Sensors
HUMICAP 180R HUMICAP180R
HUMICAP 180V HUMICAP180V
Sensor protection
Plastic grid filter DRW010522SP
Membrane filter DRW010525SP
Stainless steel sintered filter DRW010525SP
PTFE membrane filter with stainless steel grid ASM212652SP
PTFE sintered filter DRW244938SP
Probe installation
Probe mounting clamp set, 10 pcs 226067
Probe mounting flange 226067
Probe holder, 5 pcs ASM213382SP
Plastic M12 installation nuts, pair 18350SP
Flat extension cable 1 m (3 ft) (1) CBL210649SP
Connection adapters
4 … 20 mA loop power converter UI-CONVERTER-1CB
Mounting bracket for converter 225979
USB cable for PC connection 219690
Connection cable for MI70 indicator 219980SP
Connection Cables With Open Wires
+60 °C 0.3 m (+140 °F 1 ft) HMP50Z032SP
+60 °C 0.3 m (+140 °F 1 ft) HMP50Z120
+60 °C 3 m (+140 °F 9.8 ft) HMP50Z300SP
+80 °C 1.5 m (+176 °F 5 ft) 225777SP
+80 °C 3 m (+176 °F 10 ft) 225229SP
+180 °C 1.5 m (+356 °F 5 ft) FEP 238025
+180 °C 3 m (+356 °F 10 ft) FEP 226902SP
(1) Connection cable 219980SP is also needed if this cable is used with MI70 indicator

Download

Vaisala HMP110 Humidity and Temperature Probe_DpstarGroup