Vaisala DL2000 Temperature and Humidity Data Loggers

Features

  • Industry-leading temperature and relative humidity measurement precision
  • High accuracy, adjustable timebased digital recording
  • Printed reports for any time period
  • 10-year battery
  • Ability to perform validation and continuous monitoring with the same model
  • Traceable to SI units through national metrology institutes
  • Superior alternative to chart recorders and hard-wired systems
  • Integrated high-accuracy RH sensor
Enquiry

Vaisala DL2000 Temperature and Humidity Data Loggers offer precise measurements for temperature, relative humidity, and an analog sensor of your choosing. These loggers feature internal temperature and RH sensors, along with optional external channels for current or voltage inputs. These can record various parameters like differential pressure, CO2 levels, particle counts, or conductivity. Additionally, Vaisala DL2000 logger can include a Boolean channel for door switches or alarm contacts. All calibrations in Vaisala DL2000 logger are traceable to SI units through national metrology institutes.

1) The measurement results are traceable to the international system of units (SI) through national metrology institutes (NIST USA, MIKES Finland, or equivalent) or ISO/IEC 17025 accredited calibration laboratories.

Vaisala DL2000 data logger is perfect for standalone or networked setups. You can connect it directly to a PC using USB or integrate it into an existing network via Ethernet, Power over Ethernet, or WiFi. Each logger comes with a 10-year battery and onboard memory, ensuring continuous recording at the measurement spot. With its self-sufficient power and storage capability, data remains unaffected by network or power disruptions.

Vaisala DL2000 data loggers can be used with Vaisala software, either viewLinc or vLog, to download, display, and analyze environmental data. The viewLinc offers 24/7 multi-stage alarm alerts, remote real-time monitoring, and continuous data recording. The vLog is a simple solution for validation and mapping tasks. The measurement results are traceable to international standards through accredited calibration labs. Reports are customizable and exportable to spreadsheets and PDFs to meet regulatory requirements.

Key Benefits

  • Battery-powered with large onboard memory
  • Validate & monitor with the same device
  • Accurate, stable measurements

Dpstar is a leading supplier of environmental measurement sensors for temperature, relative humidity, pressure, dew point, CO2, and other environmental condition monitoring for industrial process application and research. Since the ’90s, we earned a reputation as a trusted partner to our clients through our commitment and dedication. We are an authorized distributor and supplier of measuring sensors solutions from renowned manufacturers Vaisala. Vaisala is a global leader in environmental and industrial measurement. Building on 80 years of experience, Vaisala provides observations for a better world. Vaisala is a reliable partner for customers around the world, offering a comprehensive range of innovative observation and measurement products and services.

Specification

General
Size 85 × 59 × 26 mm (3.4 × 2.3 × 1 in)
Weight 76 g (2.7 oz.)
Interfaces RS-232 serial, USB, WiFi, Ethernet and Power over Ethernet (vNet)
Mounting 3M Dual Lock™ fasteners
Power source Internal 10-year lithium battery (Battery life specified at +23 °C with sample interval of 1 min or longer)
Internal clock Accuracy ±1 min/month at -25 °C … +70 °C (-13 … +158 °F)
Electromagnetic compatibility FCC Part 15 and CE
EN 50581:2012
EN 55032:2012/AC:2013 Class B
EN 61326-1:2013
RoHS compliance 2011/65/EU
PC Software
Monitoring, alarming, and reporting viewLinc
Validation/mapping GxP environments vLog VL for validated
vLog SP for non-validated
Adding loggers to an existing OPCcompatible monitoring system OPC Server
Channel Configuration and Recording Span
Model Channel Types
CH 1 CH 2 CH 3 CH 4
2000-20R T RH
2000-3CR T RH 4 … 20 mA
2000-35R T RH 0 … 5 VDC
2000-3AR T RH 0 … 10 VDC
2000-4BR T RH Boolean Boolean
Number of Channels Enabled1)
Sample Interval 1 2 3 4
10 seconds 14.1 days 7.1 days 4.7 days 3.5 days
1 minute 2.8 months 1.4 months 23.8 days 21.2 days
5 minutes 1.2 years 7.1 months 4.7 months 3.5 months
15 minutes 3.5 years 1.7 years 1.2 years 10.6 months
1 hour 13.9 years 7.0 years 4.6 years 3.5 years
1) Temperature channel must be enabled when the RH channel is enabled
Memory
Sample capacity 122 197 12-bit samples
Memory type Non-volatile EEPROM
Memory modes User-selectable wrap (FIFO) or stop when memory is full. User-selectable start and stop times.
Sampling rates User-selectable from once every 10 seconds to once a day.
Internal Sensors
Internal Temperature Sensor
Calibrated measurement range1) -25 … +70 °C (-13 … +158 °F)
Operating range -35 … +85 °C (-31 … +185 °F)
Initial accuracy2)
± 0.10 °C over +20 °C … +30 °C (± 0.18 °F over +68 °F … +86 °F)
± 0.20 °C over -25 °C … +70 °C (± 0.36 °F over -13 °F … +158 °F)
One Year Accuracy3)
± 0.15 °C over +20 °C … +30 °C (± 0.27 °F over +68 °F … +86 °F)
± 0.25 °C over -25 °C … +70 °C (± 0.45 °F over -13 °F … +158 °F)
Resolution 0.02 °C at +25 °C (0.04 °F at +77 °F)
Internal RH Sensor
Calibrated measurement range1) 45 %RH at +10 °C (+50 °F)
10 … 80 %RH at +25 °C (+77 °F)
45 %RH at +45 °C (+113 °F)
Operating range 0 … 100 %RH (non-condensing)
Initial accuracy2) ± 1 %RH over 10 … 80 %RH at
+20 … +30 °C (+68 … +86 °F)
± 1.5 %RH over 80 … 90 %RH at
+20 … +30 °C (+68 … +86 °F)
± 2 %RH over 10 … 90 %RH at
-20 … +70 °C (-4 … +158 °F)
One year accuracy3) ± 2 %RH over 10 … 90 %RH at
+20 … +30 °C (+68 … +86 °F)
± 3 %RH over 10 … 90 %RH at
-20 … +70 °C (-4 … +158 °F)
Resolution 0.05 %RH
1) Custom calibration points available upon request including full ICH coverage.
2) Initial accuracy includes all known influence quantities present at the time of calibration including calibration uncertainty, mathematical fit, data logger resolution, hysteresis and reproducibility.
3) One Year Accuracy includes all known influence quantities present during the operation of a data logger over the course of one year including Initial Accuracy and Long Term Drift. Not included is any drift related to atypical contamination or misuse.
Current Loop and Voltage Inputs
Input Type Current Loop Analog Voltage
Available ranges 0 … 22 mA 0 … 5 VDC, 0 … 10 VDC
Resolution 5.5 μA 0.025 % F.S.
Accuracy ±0.15 % F.S. at +25 °C
(+77 °F)
±0.15 % F.S. at +25 °C
(+77 °F)
Input impedances 75 Ω1) >1 MΩ
Isolation One common per logger One common per logger
Overload protection 40 mA max. (reverse-polarity protected) ±24 VDC max. (reverse-polarity protected)
1) Termination resistance plus approximately 0.4 volt drop through a protection diode.

Download

Vaisala DL2000 Temperature And Humidity Data Loggers_DpstarGroup