Lutron DW-6093 – 3 Phase Power Analyzer

Features

  • Analysis for 3 phase multi-power system, 1P/2W, 1P/3W, 3P/3W, 3P/4W.
  • Current probe input signal/ranges with selection:
  • Meter can cooperate with other universal current probes.
  • Voltage & Current are the True RMS value.
  • True Power (KW, MW, GW).
  • Apparent Power (KVA, MVA, GVA).
  • Reactive Power (KVAR, MVAR, GVAR).
  • Watt-Hour (WH, SH, QH, PFH).
  • Power Factor (PF), Phase Angle (Degree).
  • Voltage range : 10 to 600 ACV.
  • Current range : 0.2 to 1200 ACA, CP-1201.
  • Programmable CT ratio (1 to 600) and PT ratio (1 to 1000).
  • ACV input impedance is 10 Mega ohms.
  • Safety Standard : IEC 1010, CAT III 600V.
Enquiry

Lutron DW-6093 is a 3-phase power analyzer designed for analyzing various types of power systems. It comes with 3 current probes and allows for easy probe replacement without needing recalibration. The analyzer can handle different input signals and ranges for both voltage and current, and it can work with other current probes as well. It includes test leads, alligator clips, clamp probes, an adapter, SD memory card, and carrying bag. It measures true RMS values for voltage and current, along with true power, apparent power, reactive power, watt-hour, power factor, and phase angle. It has a wide voltage and current range, programmable CT and PT ratios, and meets safety standards. It features a built-in clock and calendar for real-time data recording with an SD memory card, and data can be easily transferred to a computer for further analysis. It can be powered by batteries or an adapter and offers computer data output with optional cables and software. Optional current probes are available, and users can request the meter without probes.

Specification

Circuit Custom one-chip of microprocessor LSI circuit
Display • LCD Size : 81.4 X 61 mm ( 3.2 X 2.4 inch )
• Dot Matrix LCD (320 X 240 pixels ) with back light
Measurement • ACV
• ACA
• AC WATT ( True Power )
• AC WATT( Apparent Power )
• AC WATT( Reactive Power )
• Power factor
• Phase angle
• Frequency
Wire connections 1P/2W, 1P/3W, 3P/3W, 3P/4W.
Voltage ranges 10 ACV to 600 ACV, auto range.
Current probe input signal and range • Current probe input signal volage ( ACV ) :
200mV/300mV/500mV/1V/2V/3V.• Current probe input current range ( ACA ) :
20 A/200A/2000A (1200 A)/30A/300A/3000A• Meter can cooperate the universal current probe.
Safety standard IEC1010 CAT III 600 V.
ACV input impedance 10 Mega ohms.
Range select ACV : Auto range.
ACA : Manual range.
Clamp  frequency response 40 Hz to 1 KHz.
Spec. tested frequency 45 to 65 Hz
Over load protection • ACV  : 720 ACV rms
• ACA : 1300 ACA with clamp probe
* For the Clamp ,CP-1201
Over Indicator • LCD display show ” OL “.
• The data save into the SD card will show ” 9999 ” or ” 999 ”
( overleap the decimal point ).
Under Indicator • LCD display show ” UR “.
• The data save into the SD card will show ” 9999 ” or ” 999 ”
( overleap the decimal point ).
Data Hold Freeze the display reading.
Data Record SD Card Record.
Sampling Time Approx. 1 second.
Power ON/OFF Manual OFF by push button
Real time  data logger • Real time data logger, saved the data into SD memory card and down load the all the measured value with the time information ( year/month/data/ hour/mimute/second ) down load to the Excel

• Integration time for data logger : 2 seconds to 7200 seconds, the during of setting step are 2 seconds.

Data Output USB/RS232
* Computer interface
RS232 computer serial interface :

• Connect the optional USB cable
USB-01 will get the USB plug.

• Connect the optional RS232 cable
UPCB-02 will get the RS232

Operating  Temperature 0 to 50 °C( 0 to 122 °F ).
Operating Humidity Less than 80% R.H..
Power Supply • DC 1.5V, AA ( UM-3 ) Battery X 8 PCs (Alkaline or heavy duty battery).
• AC to DC 9V power adapter.
Power  Consumption • Meter : 300 DCmA
• Clamp : 34 DCmA.
Clamp max. conductor  Size 50 mm ( 2.0 inch ) Dia.
* For the Clamp ,CP-1201
Weight • Meter: 948g ( includes batteries )
• Clamp ( includded cable ) : 467g
Dimension • Meter :
225 X 125 X 64 mm
( 8.86 X 4.92 X 2.52 inch )• Clamp :
210 X 64 X 33mm
( 8.3 X 2.5 X 1.3 inch )• Clamp Jaw :
86 mm (3.4 inch)- outside
Accessories Included • Instruction manual………………….. 1 PC
• Test Leads (TL88-4AT)…………. 1 Set (4 PCs)
• Alligator clips (TL88-4AC)……….1 Set (4 PCs)
• Clamp Probe ( CP-1201 )……..3 PCs
• AC to DC 9V adapter……………..1 PC
• SD card ( 2 G )……………………… 1 PC
• Carrying bag………………………….1 PC
Optional Accessories • 2000 Amp current probe, CP-2000
• 200 Amp current probe, CP-200
• Flexible 3000 Amp current probe, CP-3000
• USB Cable , USB-01
• RS232 cable, UPCB-02
• Data Acquisition software, SW-U811

Download

Lutron DW-6093 – 3 Phase Power Analyzer-DpstarGroup