Fibre Glass Insulated Heating Cables – Flexelec CV/I

Features

  • Highly flexible.
  • High power: 125 W/m.
  • High temperature, up to 450°C.
  • Not protected against humidity.
  • Minimum bend greater than 10 mm.
  • Power cable: standard length 500 mm.
  • CV/I: fiberglass insulated heating elements with stainless steel braid and earthing conductor.
Enquiry

Through our deep knowledge and experience, we are able to supply electrical heat tracing systems and solutions to achieve both dynamic heat up and temperature maintenance applications in Oil and Gas, Palm Oil, Food Industry, and others. To maintain a static or a moving product at an even temperature, Dpstar provides a wide range of heating cables. We understand your requirements and we are specialists in Electrical Heat Tracing solutions and provide reliable systems and solutions. Dpstar is responsible, trustworthy, and accountable you can count on.

The heater cable is build up with a heating part and a cold part. The heating cable FLEXUNIT could be done with different insulation and options. Our heating cables are used in the refrigeration industry, house appliances, any equipment or machine requiring freeze protection. Dpstar offer a complete range of heating cable, heating, and heater tape with silicon or thermo plastic insulation.

Fibre glass insulated CV/I heating cables is mainly for use in laboratories and in industrial applications when it is required to heat quickly to a high temperature. These cables are very flexible but as they are not sealed they can be used only in a dry atmosphere, and in compliance with the electrical protection instructions in force. To ensure that these heating elements enjoy a long service life, we recommend using a control device.

Characteristics

  • Highly flexible.
  • High power: 125 W/m.
  • High temperature, up to 450°C.
  • Not protected against humidity.
  • Minimum bend greater than 10 mm.
  • Power cable: standard length 500 mm.
  • Fiberglass insulated cables with stainless steel braid and earthing conductor.
  • Special production on request.

Applications

  • Taking vacuum to its extremes with heating elements.
  • Bring gas piping, vacuum pumps or baking analysis stands up to 450°C or 900°C, using the properties of glass fibre and silica fibre heating flexes and tapes.

Specification

Model CV/I
Heating wire Nickel-Copper or Nickel-Chrome
Diameter 5 mm
Max. power 125 W/m
Voltage Any voltage on request up to 230 V
Permissible surface temperature up to + 450°C
Tolerances Power : ± 10 %
Diameter : ± 0.5 mm
Length : ± 1 %
Connection insulation Fibre class
Protection With earth
Ingress protection code IP 40
Insulation Class CLASS I (earthing)
Heating length (m) 1 2 4 6 8 10
Power (W) 125 250 500 750 1000 1250