Maltec-T MT8000F Thermocouple Multipoint Sensor – Contacting Fixture Design

Features

  • Effectively oversee temperature profiles across various applications, such as identifying hot spots in reactors
  • Single-step insertion capable of accommodating up to 60 independent measurement points
  • Compact design for individual measurement points
  • Lowers the expense of individual measurement points
  • Sensing elements are replaceable individually on-site
  • A full assembly consisting enclosure, sensor and protective tube can be ordered
Enquiry

Matec-T MT8000F Thermocouple Multipoint Sensor – Contacting Fixture Design

The Maltec-T MT8000F Multipoint Sensor is adaptable, robust, and designed for lasting reliability and a long lifespan. It utilizes single ungrounded thermocouples for individual measurements, with a maximum of 20 measurement points. These sensors are to be used for temperature profile measurements where extremely detailed local resolution is unnecessary.

Configuration

You can order the Maltec-T MT8000F with or without a thermowell, and it available in three types of sensor configurations:

1) Individual Guide Tube Design
The individual guide tube design makes it easy to replace individual elements. Mineral insulated thermocouple elements are placed inside each guide tube and directed to the specific measuring spot. If ordered with spring-loaded fittings, you’ll have quick thermal response, but inside of the thermowell won’t be sealed. When ordered with compression fittings, the thermowell is sealed, but the thermal contact isn’t as effective.

2) Radial Spring Design
This design provides good thermal contact between the thermocouple and thermowell, which helps it respond quickly. A radial spring presses the thermocouple against the inside wall of the thermowell, and the flattened MI cable touches it completely. This setup guarantees the best response time. If you order it without a thermowell, it will be sent in a coil. You can’t replace the individual thermocouples.

3) Laminated Spring Design
This design provides good thermal contact between the thermocouple and thermowell, which helps it respond quickly. A laminated spring presses the thermocouple against the inside of the thermowell. This setup is good if the mounting flange is angled to the thermowell. The advantage of this design is that the sensor can bend to fit the shape of the thermowell, like an oil dipstick. If you order this sensor without a thermowell, it will be sent in a coil. The individual thermocouples can’t be replaced.

Contacting Fixture Design

Dpstar Group is the largest manufacturer of thermocouples based in Malaysia. We design and manufacture a complete line of high-quality standard and custom temperature sensors including thermocouples, RTD’s, thermowells, and float switches as well as a wide selection of temperature accessories. Through our engineering capabilities and 30 years of experience, our trademark brand Maltec-T is the only CE-certified manufacturer for thermocouples in Malaysia. With extensive experience, unique technology, and hard commitment, we become one of the best quality suppliers in the temperature sensors field. We offer a full range of design services to provide you with the benefit of our knowledge and experience.

Specification

Functional Number of measuring points: 2 to 20
Temperature limits:
– Type E and J: -40 to 750 °C (-40 to 1382 °F)
– Type K and N: -40 to 800 °C (-40 to 1472 °F)
Physical Length limits:
1) 10 m (33 ft) with thermowell – all designs.
2) 30 m (99 ft) without thermowell – Radial and Laminated designs only.
Physical dimensions – Thermowell Diameter for Guide Tube and Laminated Spring Design:
Number of mesurement points O.D. I.D.
2-in. schedule 80
2 to 5 60.33 mm 2.34 inch 49.25 mm 1.94 inch
2½-in. schedule 80
6 to 8 73 mm 2.9 inch 59 mm 2.4 inch
3-in. schedule 80
9 to 20 88.9 mm 3.5 inch 73.7 mm 2.9 inch
Physical dimensions – Thermowell Diameter for Radial Spring Design:
Number of mesurement points O.D. I.D.
2 to 8 73.0 mm 2.9 inch 59.0 mm 2.3 inch
9 to 20 88.9 mm 3.5 inch 73.7 mm 2.9 inch
Performance Ambient temperature limits: For the enclosures and transmitters is –40 to 80 °C (–40 to 176 °F
Insulation resistance: Greater than 1000 MOhm at room temperature, test voltage is 500 VDC
Accuracy – Limits of Error Interchangeability for Class I Thermocouples:
Type
E 1.5 °C or 0.004 |t|(1), -40 to 750 °C
J 1.5 °C or 0.004 |t|, -40 to 750 °C
K 1.5 °C or 0.004 |t|, -40 to 800 °C
N 1.5 °C or 0.004 |t|, -40 to 800 °C

Ordering Information

Model Product description
MT8000F  Maltec-T MT8000F Thermocouple Multipoint Profiling Sensor – Contacting Fixture Design, Tolerance Class 1
Code Element fixation method
1 Individual guide tubes, compression fittings, replaceable elements
2 Individual guide tubes, spring loaded fittings, replaceable elements
3 Laminated spring design, compression fittings, fixed elements
4 Radial spring design, fixed elements
Code  Thermocouple type Operating temperature range
E1 E -40°C to 750°C -40°F to 1382°F
J1 J -40°C to 750°C -40°F to 1382°F
K1 K -40°C to 8050°C -40°F to 1472°F
N1 N -40°C to 8050°C -40°F to 1472°F
Code Number of measurement points
3 3
8 8
12 12
16 16
20 20
XX Other quantities (minimum. 02; maximum. 20)
Code  Transmitter mounting hardware Maximum measuring points
A With mounting hardware 20
N  With no transmitter hardware (terminal strips only) 20
Code Enclosure type Material IP rating  NEMA rating
A EEx d CENELEC Flameproof Approved (consult factory for availability) Aluminum 65 NEMA 4
B EEx e CENELEC Increased Safety Approval (consult factory for availability) Aluminum 65 NEMA 4
C EEx i Intrinsically Safety acc. EN 50014 and EN 50020 with manufacturer declaration for Ex i use in Zone 1 Aluminum 65 NEMA 4
D Standard aluminum Aluminum 65 NEMA 4
E Standard polyester Polyester 65 NEMA 4
S Special enclosure type (Configuration Data Sheet required)
Code Enclosure entry
1 Single multi-core cable gland
2 Multiple cable glands M20 x 1.5 (one per measurement point)
3 Han-Plug connection IP65
4 Customer specified (Configuration Data Sheet required)
Code  Thermowell material Maximum temperature
D Stainless steel – DIN 1.4404 (ANSI 316L) 450 °C 842 °F
P Heat resistant steel–DIN 1.7380 (ANSI 182-F22) 800 °C 1472 °F
S Special tube material – customer specified (Configuration Data Sheet required) Consult factory
N No thermowell
Code Thermowell diameter
A Standard
C Customer specified (Configuration Data Sheet required)
Insertion length “U”
01000 1000 mm (39 inch) Length code is in mm. To convert to mm multiple the length in inches by 25.4
02000 2000 mm (79 inch)
03000 3000 mm (118 inch)
05000 5000 mm (197 inch)
07000 7000 mm (276 inch)
10000 10000 mm (394 inch)
XXXXX Other lengths maximum 10000mm [394 inch with thermowell] (maximum 30000mm [1181 inch] without thermowell and radial spring design only))
Measurement point distribution
A Equally distributed points
C Customer specified (Configuration Data Sheet required)
Code First measurement point location-distance from base of mounting flange
00500 500 mm (20 in)
01000 1000 mm (39 in)
02000 2000 mm (79 in)
03000 3000 mm (118 in)
04000 4000 mm (158 in)
XXXXX Other lengths
Code  Mounting style – flange material= DIN 1.4404 (ANSI 316L) Process connection
F36  Flanged, ANSI 2-in. Class 300 RF
F74  Flanged, ANSI 2½-in. Class 300 RF
F76  Flanged, ANSI 3-in. Class 300 RF
F54  Flanged, ANSI 2-in. Class 600 RF
F78  Flanged, ANSI 2½-in. Class 600 RF
F80  Flanged, ANSI 3-in. Class 600 RF
F72  Flanged, ANSI 2-in. Class 900 RF
F82  Flanged, ANSI 2½ -in. Class 900 RF
F84  Flanged, ANSI 3-in. Class 900 RF
D26 Flanged, DIN DN 50 PN 25/40
CDS Customer specified (Configuration Data Sheet required)
Code Additional options
Special tagging and configuration options
C1 Customer specified tagging and transmitter configuration – Configuration Data Sheet Required
Thermowell options
Q8 Thermowell material tagging and transmitter configuration (configuration Data Sheet Required)
R01 Thermowell pressure testing
R03 Thermowell dye penetration  testing
R07 Full penetration weld
R16 Ring joint flange (ASME B16.5 ANSI flanged thermowell only)
Process connection options
P01 Leak check valve
Typical model number: MT8000F    2   J1   A   D   1   D   A   01000   A   0500   F36   R01   P01