Siemens MAG 8000 Battery-Operated Water Meter

Features

  •  Compact or remote solution with factory mounted cable and
    customer setting from factory
  • IP68/NEMA 6P enclosure. Sensor can be buried
  • No moving parts means less wear and tear.
  • Up to 6 to 10 years maintenance-free operation in typical
    revenue application
  • Embedded self-testing and alarm/fault detection feature
  • Internal data logger
Enquiry

Siemens MAG 8000 Battery-Operated Water Meter range of flowmeters powered by batteries offers the versatility to install a dependable water flow measurement system in almost any location while maintaining accuracy and performance.

Specification

Nominal size From DN 25 – 1200 (1″ to 48″)
From DN 50 – 600 (1” – 24”) for CT version under the MI001 and OIML R49 Class I & II
Accuracy 0.2% ± 2mm/s and 0.4% ± 2mm/s
Input / Output 2 passive outputs
Communication Local Modbus RTU IrDA (Infrared comm.), Modbus RS 232/485, Radio Encoder (Sensus Protocol), 4G LTE M/NB IoT
Power supply nternal or external battery pack
12-24 V AC/DC and 115-230 V AC
Operating pressure Max. 40 bar (Max. 580 psi)
Ambient Temperature From -20 to 60 °C (-4 to 140 °F)
Medium temperature From 0 to 70 °C (32 to 158 °F)
From 0.1 to 50 °C (32 to 122 °F) (SITRANS F M MAG 8000 CT)
Liner EPDM
Electrodes Hastelloy C 276
Enclosure IP68 (NEMA 6P)
Material Transmitter: Stainless steel top housing (AISI 316) and coated brass bottom.
Sensor: Carbon steel
Approvals WRAS, KTW, DVGW 270, ACS, Belgaqua, NSF/ANSI Standard 61, MID (EU), OIML R49, MCERTS Sira Certificate No. MC080137/00
NMI 1

Download

Siemens MAG 8000 Battery Operated Water Meter_DpstarGroup