Siemens SIWAREX WL230 SB-S SA Load Cell

Enquiry
Category:

Siemens SIWAREX WL230 SB-S SA Load Cell, a shear beam load cell, is well-suited for applications in hopper, overhead rail, and platform scales.

Dimensional drawings
SIWAREX WL230 SB-S SA load cell, dimensions in mm (inch)

 

Specification

Recommended reference voltage Uref 5 … 12 V DC
Input resistance Re 1 000 ± 10 Ω
Output resistance Ra 1 004 ± 5 Ω
Zero signal TKo
0.023% Cn/5 K
Characteristic value TKc 0.017% Cn/5 K
Certificates and approvals
Accuracy class according to OIML R60
C3