Ninomiya Fiber Glass 1-Pair (Flat Type) – Thermocouple Extension Cables

Features

2 elemental compensating wires are served and braided with glass-yarn separately to be insulated, bound in parallel, shielded with tin-coated annealed copper wires (B), braided with glass-yarn, and braided with stainless wires (C) for protection at the outermost.

Enquiry

Ninomiya Fiber Glass 1-Pair (Flat Type) – Thermocouple Extension Cables

Two elemental compensating wires are individually insulated with glass yarn, braided, and then bound together in parallel. They are shielded with tin-coated annealed copper wires (B) and further protected by a braided layer of glass yarn and stainless steel wires (C) on the outermost surface.

Specification

Parts No. Construction No. of pairs Conductor Insulation OD of pair mm OD of cabling mm Shield
thickness
mm
Sheath
thickness
mm
Finished
OD
mm
Standing
No./mm
OD
mm
Thickness
mm
OD
mm
12/0.18x1P □X-H A 1 12/0.18 0.7 0.4 1.5 1.5×3.0 0.3 2.1×3.6
12/0.18x1P □X-H-IS B 1 12/0.18 0.7 0.4 1.5 1.5×3.0 0.3 0.3 2.7×4.2
12/0.18x1P □X-H-SOS C 1 12/0.18 0.7 0.4 1.5 1.5×3.0 0.3 0.3 2.7×4.2
7/0.3x1P □X-H A 1 7/0.3 0.9 0.4 1.7 1.7×3.4 0.3 2.3×4.0
7/0.3x1P □X-H-IS B 1 7/0.3 0.9 0.4 1.7 1.7×3.4 0.3 0.3 2.9×4.6
7/0.3x1P □X-H-SOS C 1 7/0.3 0.9 0.4 1.7 1.7×3.4 0.3 0.3 2.9×4.6
20/0.18x1P □X-H A 1 20/0.18 1 0.4 1.8 1.8×3.6 0.3 2.4×4.2
20/0.18x1P □X-H-IS B 1 20/0.18 1 0.4 1.8 1.8×3.6 0.3 0.3 3.0×4.8
20/0.18x1P □X-H-SOS C 1 20/0.18 1 0.4 1.8 1.8×3.6 0.3 0.3 3.0×4.8
30/0.18x1P □X-H A 1 30/0.18 1.2 0.4 2 2.0×4.0 0.3 2.6×4.6
30/0.18x1P □X-H-IS B 1 30/0.18 1.2 0.4 2 2.0×4.0 0.3 0.3 3.2×5.2
30/0.18x1P □X-H-SOS C 1 30/0.18 1.2 0.4 2 2.0×4.0 0.3 0.3 3.2×5.2
7/0.45x1P □X-H A 1 7/0.45 1.35 0.4 2.15 2.15×4.3 0.35 2.9×5.0
7/0.45x1P □X-H-IS B 1 7/0.45 1.35 0.4 2.15 2.15×4.3 0.3 0.35 3.5×5.6
7/0.45x1P □X-H-SOS C 1 7/0.45 1.35 0.4 2.15 2.15×4.3 0.35 0.3 3.5×5.6
4/0.65x1P □X-H A 1 4/0.65 1.57 0.4 2.37 2.37×4.74 0.35 3.1×5.4
4/0.65x1P □X-H-IS B 1 4/0.65 1.57 0.4 2.37 2.37×4.74 0.3 0.35 3.7×6.0
4/0.65x1P □X-H-SOS C 1 4/0.65 1.57 0.4 2.37 2.37×4.74 0.35 0.3 3.7×6.0
7/0.65x1P □X-H A 1 7/0.65 1.95 0.4 2.75 2.75×5.5 0.35 3.5×6.2
7/0.65x1P □X-H-IS B 1 7/0.65 1.95 0.4 2.75 2.75×5.5 0.3 0.35 4.1×6.8
7/0.65x1P □X-H-SOS C 1 7/0.65 1.95 0.4 2.75 2.75×5.5 0.35 0.3 4.1×6.

Please fill in □ with a type (symbol) of a compensating cable to order.
We also manufacture outer shields for tin-coated annealed copper wires (OS) . Please contact us with any requests.

Download

Ninomiya Fiber Glass 1-Pair (Flat Type) – Thermocouple Extension Cables-DpstarGroup