Shimaden CP2RT Series – Temperature Converter

CP2RT functions to convert thermocouple and R.T.D. input signals into DC signals. Standard feature: Isolation, Linear output and Burnout function 6 toxic substances, which are subject to RoHS regulations, are contained. However, the amount of toxic substances contained does not exceed standardized values.

Enquiry

Shimaden CP2RT Series serves as a temperature converter, transforming thermocouple and R.T.D. input signals into DC signals. It includes features such as isolation, linear output, and a burnout function. Additionally, it complies with RoHS regulations regarding six toxic substances, ensuring their presence remains within standardized limits.

Specification

Thermocouple Input T, E, J, K, N, R, S, B
Conversion accuracy ±0.3% FS / Linearized output (at 23 °C)
Influence of ambient temperature ±0.2% FS for temperature change of 10 °C
Measurement range Refer to “Ordering Information”.
Conversion output Refer to “Measuring Range Codes”
Cold Junction Temp. Compensation Range 5–45°C
Input Resistance 1MΩ
External Resistance Tolerance 100 Ω max
R.T.D. Input Pt100 / JPt100 (3-wire type)
Conversion Accuracy ±0.3% FS / Linearized output (at 23 °C)
Influence of ambient temperature ±0.2% FS for temperature change of 10 °C
Measurement range Refer to “Measuring Range Codes”
Conversion output Refer to “Ordering Information”.
Amperage 1mA
R.T.D. Lead Wire Tolerable Resistance 5Ω max. per wire
Response speed 500ms max. (0–90%)
Reproducibility ± 0.1% FS
Burnout Circuit Standard (upscale)
Conversion Output Adjustment Range ±4% (ZREO and SPAN)

Ordering Information

ITEMS CODE SPECIFICATIONS
SERIES CP2RT- Temperature Converter
INPUT 1 Thermocouple, T, E, J, K, N, R, S, B Input Resistance:1MΩ
2 R.T.D. (Pt100/JPt100), 3-wire type Amperage: 1mA
CONVERSION OUTPUT 1 0–10mV DC / FS Output Resistance: 5 Ω
2 0–100mV DC / FS Output Resistance: 50 Ω
3 0–1V DC / FS Max. Current: 2mA
4 0–10V DC / FS Max. Current: 2mA
5 1–5V DC / FS Max. Current: 2mA
6 4–20mA DC / FS Load Resistance: 600Ω max
9 Others (Please consult before ordering.)
POWER SUPPLY 02- 24 V DC±10%
13- 100–110 V AC±10% 50/60Hz
14- 110–120 V AC±10% 50/60Hz
15- 200–220 V AC±10% 50/60Hz
16- 220–240 V AC±10% 50/60Hz
99- Others (Please consult before ordering.)
INPUT STANDARD F JIS PT100
J JIS JPT100 and Thermocouple
D DIN
A ANSI
X Others (Please consult before ordering.)
TYPE OF INPUT T Thermocouple T Cold Junction Temperature Compensator
(Externally installed)
E Thermocouple E
J Thermocouple J
K Thermocouple K
H Thermocouple N
R Thermocouple R
S Thermocouple S
B Thermocouple B Cold Junction Temperature Compensator (Not Available)
P R. T. D. Pt100
X Others (Please consult before ordering.)
MEASURING RANGE °°° See Measuring Range Codes.
LEGEND C °C
F °F
X Others (Please consult before ordering.)
REMARKS 0 Without
9 With (Please consult before ordering.)

Download

Shimaden CP2RT Series – Temperature Converter-DpstarGroup